hotline: +48 62 741 13 80 / +48 695 515 454


POWERS:
10-48 kw
THERMAL EFFICIENCY:
>80%

VIVO

central heating furnaces for all kinds
of fuel with controller and blower

Central heating furnaces

VIVO type central heating furnaces are low temperature heating furnaces designed for water heating in both pump and gravity installations.

Advantages

  • STEEL OF THE HIGHEST QUALITY – boiler sheets P265GH
  • EFFICIENCY – the efficiency of the boilers going up to class A
  • VERY BIG FILLING CHAMBER
  • BIG AND CONVENIENT DOOR – with an option to configure left / right
  • CLEANOUT AT THE FRONT – a convenient way to clean the boiler
  • SIMPLEST CLEANING OF THE BOILER – access to channels by opening the front door

Paliwa spalane na ruszcie:

fine coal

coal


wood

briquette

Those central heating furnaces are used for heating of residential, one or multi-family buildings, public buildings, such as schools, offices, trade buildings, production buildings and many others. VIVO central heating furnaces can be used in installations of open-heating systems only.

They are produced with the capacity of 10 - 48 kW.

In the case of the Płomyk controller, the user needs only to set the water temperature of the boiler and the controller will automatically adjust the amount of air.

Carefully matched fuel- air ratio results in the high performance of the combustion process.

Advantages of the central heating boiler: big refueling door, easy operation, especially within the range of cleaning, the central heating boiler operates in semi- automatic mode, increased life span and high efficiency.

Detailed list Technical specifications of VIVO
Type 10 15 18 22 26 32 36 48
Rated power kW 10 15 18 22 26 32 36 48
Power range kW 3-10 4-13 5-18 6-22 8-26 9-32 14-36 19-48
Boiler heating surface 1,0 1,5 1,8 2,2 2,6 3,2 3,6 4,8
Heating area do
90
do
130
130
-160
160
-180
180
-200
200
-250
250
-300
300
-400
Thermal efficiency % >=80
Maximum water temperature °C 90
Minimum temperature of return °C 60
Maximum working pressure Bar 1,5
Fuel consumption at rated power kg/h 2,0 2,3 2,6 3,2 3,6 4,3 5,0 7,7
Filling up hopper capacity kg 29 38 47 56 65 77 127 200
Required burnt gas draught Pa 20 20 22 25
Chimney hole diameter cm² 270 270 350 390
Height of chimney m 5 5 6 7
Water storage capacity dm³ 50 55 70 75 105 110 135 195
Flue diameter mm 160 180
Diameter of supply and return connecting pipe cal GZ 2"
Overall dimensions:
- width D
- height E
- height H
- depth G
- height F

mm

410
1190
1160
825
960

455
1225
1140
920
930

495
1240
1200
930
1000

515
1315
1215
950
1010

535
1315
1290
1050
1080

535
1340
1330
1075
1110

585
1450
1425
1140
1220

695
1515
1490
1190
1280
Overall dimensions - exchanger:
- width
- height
- depth

mm

410
1160
425

455
1140
530

495
1200
570

515
1215
600

535
1290
700

535
1315
725

585
1425
790

695
1490
840
Boiler weight without water kg 165 179 218 232 280 291 376 470

Control device PŁOMYK

The Płomyk control device is designed for air blow control in fine coal boilers and for switching the circulating pump in central heating installations. The control device has blow-through function that is activated when the temperature exceeds the set value. The adjustable setting of central heating pump switching. The Płomyk control device meets domestic and industrial electromagnetic compatibility standard (CE sign). The control device is characterized by a very easy operation and reliable action.

Technical specification:
  • Temperature adjustment range 35 - 80°C
  • Temperature measurement range 0 - 99°C
  • Temperature that activates circulating pump is adjustable in the range of 10 - 70°C
  • Blow-through control: 0 - 90 sec., break 1 -15 min
  • Possibility of complete blow-through switching off P - 0
  • Fluent blow adjustment
  • Operation at surrounding temperature of 0 - 40°C
  • Power supply ~230V/50Hz
  • Acceptable outputs loading: - blow max 100W - circulating pump max 100W
  • Adjustable power (revolutions) of the blower expressed in [%] from 30% to100%
  • Range of automatic power switch of the blower before the demanded temperature is obtained: 2 to 10°C
  • Relative air humidity 95%
  • IP protection level 40
  • Isolation class I
  • Dimensions (width x height x depth) 125x75x50mm
  • Electric protection 1,25 A

Boiler configurations

In the advanced boiler configuration we offer a few options:

  • we offer a selection of the location of the feeder from the left-hand / right-hand side of the boiler
  • we offer a selection of opening the door to the left / to the right
  • we offer a selection of the diameter and kind of power and return connectors
  • we offer a selection of the location of the power and return connectors
  • we offer a selection of the shape and location of the boiler flue, e.g. elbow to the left, to the top etc.

1. The output of the flue
at the back in the middle.

2. The output of the flue
at the back (the elbow to the left).

3. The output of the flue
at the back (the elbow to the right).

4. The output
of the flue upwards.

5. The output of the flue
at the back (the elbow towards the back).

6. The output of the fluefrom
the top (the elbow to the left).

7. The output of the flue from
the top (the elbow to the right).


The shape of the flue

The shape of the flue can be selected in accordance with the customer’s expectations. We offer the circular shape / the square shape / the rectangular shape.